Comparison of regulations and safety protection strategies for thermal runaway management of electric passenger vehicles between China and the United States

News2026-10-12
Reliable gas sensing to support early risk identification and full lifecycle safety protection

With the continuous popularization of electric passenger vehicles, the safety of power batteries is becoming an important issue in connecting product reliability, passenger protection, and market access. The climate conditions, fast charging demands, and environmental exposure during long-term use in different regions have raised higher requirements for battery systems and their safety monitoring capabilities.

The two major automobile markets in China and the United States are updating regulations and standards to improve the management system for thermal runaway of power batteries. Although each implementation path has its own emphasis, they all emphasize security protection, effective alarm, and verification basis.

In this context, the application value of gas detection is further extended: by identifying abnormal battery exhaust, it provides supplementary information for risk assessment and safety response, and remains effective under specified usage conditions and during the usage period.


Security protection concept: from anomaly recognition to collaborative protection

Thermal runaway of power batteries involves electrochemical reactions, gas release, temperature changes, and heat propagation. The evolution process is influenced by factors such as battery materials, state of charge, aging degree, fault type, and battery pack structure.

Facing this complex process, security protection needs to run through three links:

Prevention and identification: Control abnormal charging and discharging and temperature conditions, identify battery status changes and abnormal exhaust.

Risk control: Implement validated charging and discharging restrictions, thermal management, and other protective measures based on the risk level.

Alarm and response: Provide clear and timely prompts to the driver, support safe parking, passenger evacuation, and subsequent rescue.

Gas detection can be combined with voltage, temperature, pressure, and smoke monitoring to form multidimensional risk information. The actual protective value depends on the effective connection between detection performance, system layout, judgment logic, and protective measures.


The regulatory path between China and the United States: different focuses, jointly strengthening security management

China: Collaborative Specification for Batteries, Vehicles, and Detection Alarm Products

The management of thermal runaway in Chinese electric passenger vehicles involves three levels of requirements: power batteries, complete vehicles, and detection and alarm products.

GB 38031-2025 "Safety Requirements for Power Batteries for Electric Vehicles" has been implemented on July 1, 2026. The thermal diffusion test requires further strengthening of non ignition, non explosion, alarm and smoke protection under specified test conditions, and promoting the extension of safety evaluation from alarm time to accident consequence control and passenger protection.

GB 18384-2025 "Safety Requirements for Electric Vehicles" will also be implemented on July 1, 2026. When the rechargeable battery system emits a thermal event alarm signal as specified in GB 38031, the entire vehicle should alert the driver through clear light and sound signals, establishing a collaborative mechanism between the battery system and the vehicle alarm.

GB 47497-2026 "Fire Detection and Alarm Devices for Vehicles" will be implemented on May 1, 2027. This standard is applicable to the design, manufacturing, and inspection of detection alarms installed and used in gas and electric vehicles (excluding electric buses), covering gas detection, battery thermal runaway alarm, anti poisoning, long-term stability, and environmental tolerance. It provides specific performance evaluation criteria for detection alarm products.

United States: Parallel verification of vehicle safety performance and risk mitigation

The new regulations in the United States, centered around FMVSS No. 305a and its accompanying 49 CFR Part 561, require information on the safety, anomaly protection, alarm, and thermal runaway risk mitigation of electric drive systems.

For the light vehicle category that typically covers electric passenger vehicles, the mandatory application date of FMVSS No. 305a is September 1, 2027, with some manufacturers having transitional arrangements.

Article S13 stipulates that when the vehicle is in an active driving state and the energy storage system experiences a "thermal event" as defined by regulations, the sound and light alarm should be activated within 3 minutes of the event and continue for at least 5 minutes; The alarm system should also monitor its own readiness status.

The term 'thermal event' in regulations refers to a state where the internal temperature of the power battery system is significantly higher than the maximum operating temperature, and has a different definition from 'thermal runaway'. Therefore, this clause cannot be understood as requiring a 3-minute advance alarm before thermal runaway.

49 CFR Part 561 further requires manufacturers to provide technical information on alarm systems, thermal runaway, and thermal diffusion risk mitigation, including system design, risk analysis, and verification information, to support the review of the effectiveness of safety measures when requested by regulatory agencies.

Comparison of Main Requirements between China and the United States

Gas release mechanism: early warning value of reliable low concentration detection

Abnormal battery exhaust contains combustible gases such as hydrogen, carbon monoxide, and other components. The time, concentration, and rate of gas occurrence vary with the battery system and fault conditions.

A study published in Cell Reports Physical Science in 2025 conducted abuse testing on commercial lithium-ion batteries with different material systems, structures, and charge states. Under the tested conditions, researchers detected tens to hundreds of ppm of hydrogen gas in the exhaust before thermal runaway; After stopping the application of abusive conditions based on early hydrogen signals, the tested case avoided thermal runaway.

The core value of reliable low concentration hydrogen detection is to buy time for risk assessment and protective response. Identifying early abnormal emissions and concentration changes can help the system obtain supplementary information before the risk further develops.

Real usage environment: Wide temperature range is the basic condition for reliable gas detection

Both China and the United States have vast geographical spans. Vehicles operating in different regions may experience severe cold, high temperatures, as well as significant seasonal and diurnal temperature differences.

The regional ambient temperature and the temperature of the sensor installation location have different meanings. The actual temperature conditions of sensors are also affected by installation location, battery pack thermal management, local heating, and vehicle operating status.

Therefore, hydrogen, carbon monoxide, and hydrogen sulfide sensors for safety monitoring must maintain effective detection within the temperature range of the actual daily application environment of electric passenger vehicles. The wide temperature range evaluation should cover both:

Low temperature start-up and recovery time;

Zero point, sensitivity, and response time at different temperatures;

Output stability during temperature changes;

Performance retention after high temperature exposure and temperature cycling.

Long term environmental exposure: Anti silicon poisoning support for sustained and effective protection

The use of sealants, adhesives, lubricants, and other organic silicon substances in vehicle manufacturing and maintenance processes may lead to a decrease in sensitivity of some catalytic gas sensing elements, and even permanent damage. The specific impact depends on the sensing principle, material system, pollutant type, and exposure conditions.

For gas sensors that undertake safety warning functions, the ability to resist silicon poisoning is related to the effectiveness of detection within the specified service life.

The power on, communication, and electronic self-test are normal, but it cannot fully prove that the sensing element still has the expected gas response capability. Therefore, reliability verification should cover sensing elements, gas transmission paths, alarm outputs, and related linkage.

Security Protection Strategy: From Component Performance to System Effectiveness

Gas detection should be designed in conjunction with the vehicle thermal runaway management architecture, and application verification should be carried out around the following capabilities:

The arrangement of gas sensors should consider the gas transmission path between the faulty cell and the detection point, and confirm that the abnormal exhaust at the most unfavorable position can still be identified within the specified time.

The alarm and protection strategies should be combined with gas concentration, change trends, and other battery status information, and validated for driving, charging, and parking states. Through this process, the performance indicators of the sensor are implemented as the safety protection capability under actual vehicle conditions.

ProSense Early Gas Detection Solution for Transportation Safety

As an industry leader in advanced gas sensing technology, ProSense always adheres to driving technological innovation with real application scenarios. ProSense adopts a fuel cell technology platform and self-developed catalyst system to provide gas sensing solutions for power batteries for vehicle enterprises, battery system manufacturers, and vehicle detection and alarm equipment manufacturers. It supports abnormal exhaust recognition, early risk warning, and multi parameter collaborative monitoring of lithium-ion and new generation solid-state battery technology for power batteries.

The solution revolves around three key application requirements:

Low concentration reliable detection, supporting early risk identification.

Identifying abnormal signals of hydrogen, carbon monoxide, and hydrogen sulfide, combined with concentration changes and battery status parameters, provides a perceptual basis for grading warning and safety response.

Maintain wide temperature range performance and adapt to complex vehicle environments.

Pay attention to the impact of temperature changes during cold start, high temperature shutdown, and charging/discharging processes on detection performance, and support continuous monitoring under different usage conditions.

Anti silicon poisoning ability, supporting long-term effective operation.

In response to pollution factors such as siloxanes, attention should be paid to the gas response ability after environmental exposure, providing support for reliable detection within the prescribed service life.

ProSense combines advanced gas sensing technology with reliability engineering to support partners in product selection and system integration. It converts gas information into effective data that can be used for risk assessment, providing a reliable sensing foundation for power battery safety management.

Responding to real needs with technology and supporting safe travel with reliable perception

The continuous improvement of regulations and standards in China and the United States is driving the development of more systematic and verifiable management of thermal runaway in electric passenger vehicles.

Wide temperature range, resistance to silicon poisoning, and low concentration reliable detection jointly constitute important evaluation dimensions for vehicle gas sensing: wide temperature range supports effective operation under different climates and working conditions; Anti silicon poisoning supports long-term performance maintenance; Low concentration detection supports earlier identification of abnormal exhaust.

ProSense will continue to promote the collaboration of sensing technology, reliability verification, and system applications around real application needs, providing technical support for partners to improve early risk identification and security protection strategies.

Empowering transportation safety with advanced gas sensing technology, helping global vehicle partners win consumer trust, and enhancing brand value.

About ProSense

ProSense is a high-tech enterprise dedicated to the research and manufacturing of advanced gas sensors, committed to providing high-performance and high reliability sensing solutions for global customers. The company continues to invest in core technology research and development, overcome key pain points in the industry, and continuously lead the development direction of gas sensing technology. With innovative products and excellent quality, ProSense is gradually growing into an important promoter and leader in the global gas safety monitoring field.
ProSense adheres to the full stack self-developed technology route, and has established a kilogram level gas sensor catalyst research and development base and an automated production aging calibration system for millions of gas sensors per year. Its product line covers the fields of toxic and harmful, flammable and explosive, and environmental gas detection; ProSense's multiple innovative products have become core sensing components in vertical fields such as smart firefighting, industrial testing, and energy storage safety.

Contact Us
Contact Us
Online Service
Provide comprehensive customer service through real-time communication
Consult Now
Official Flagship Store
Build a first-class gas sensing solution provider
Wechat Official Account
Follow the official WeChat QR code of ProSense
View QR Code